Pisonics PS7000 Acoustic-Impedance vs Clamp-on Ultrasonic Density Meter

The PS7000 reads acoustic impedance at a wetted probe flush with the pipe bore; a clamp-on ultrasonic density meter transmits through the pipe wall from outside. Three differences decide most projects: lined pipe, entrained air, and whether you are willing to maintain acoustic couplant.

Feature comparison

Feature Ultrasonic Slurry Density Meter 行业通用 Clamp-on Ultrasonic Density Meter
Measurement principle Single-probe acoustic-impedance reflection: sapphire window contacts slurry, Chirp (linear-FM) wideband, non-nuclear Externally-clamped through-transmission: ultrasound crosses pipe wall + liner + slurry; density from sound speed / attenuation
Mounting Flanged measuring spool on a straight run (integral / remote) Transducers clamp on the pipe exterior; non-invasive, movable, no pipe cutting or shutdown
Sensing contact Sapphire window wetted, flush with the bore; the transducer sits behind it and does not protrude into the flow Fully external; no contact with the medium
Pipe lining Measurement bypasses pipe wall and liner; unaffected by liner material; spool can be specified with PTFE / rubber / ceramic liner Must penetrate pipe wall and liner; strongly absorbing liners (rubber, thick PTFE, ceramic, cement) attenuate heavily and often cannot be measured
Bubbly slurry Keeps measuring in bubbly slurry — a stable reading in the presence of gas, not accurate density at any gas fraction; outputs a 0–100 aeration index and a bubble flag Long transmission path; bubble scattering lowers SNR; readings drift or lose lock
High solids / attenuation 0–80 % mass concentration Tends to be un-penetrable under high-solids, strongly attenuating conditions
Acoustic coupling Slurry is the coupling medium; no external couplant; smooth sapphire window resists scaling Couplant required between transducer and pipe; dries / migrates with time, temperature and vibration; periodic check or re-apply
Accuracy ±1 % FS; datasheet publishes ±1 % mass concentration Affected by pipe material / wall thickness / liner / coupling; typically ±5–10% on lined pipe or worse
Pipe-wall dependence Independent of pipe material and wall thickness Depends on pipe material, wall thickness, scale and uniformity; re-calibration needed after pipe change or corrosion
Full-pipe requirement No full-pipe requirement; can measure small flows Transmission usually needs a full pipe and avoidance of top-of-pipe gas
Medium temperature 0–80 °C standard; 120 °C high-temperature version to order Limited by couplant temperature rating and hardware
Long-term maintenance No moving parts and no consumables; 360 local history records retained in Flash Periodic couplant check / re-application and re-calibration
Output / comms 4-20 mA ×2 + RS485 Modbus-RTU (optional 4G) Model-dependent
Ex / certification Optional Ex d IIC T6 Gb; CE Model-dependent
Mounting flexibility One-time shutdown to flange in the measuring spool Non-invasive; can be installed and relocated without shutdown (its structural advantage)
Best-fit conditions Lined / bubbly / high-solids lines, long-term stable continuous measurement, DCS / hazardous area Pipe cannot be cut or shut down, temporary or mobile measurement, clean full pipe without a (thick) liner

Takeaway

When the pipe is clean and full with no (thick) liner, or the site cannot be drilled or shut down and a temporary / mobile reading is needed, a clamp-on ultrasonic meter is flexible and non-invasive and remains a useful option. The PS7000 is the better choice when:

  1. the pipe is lined — the clamp-on must cross the wall and liner and strongly absorbing liners often cannot be measured, whereas the PS7000 window is inside the pipe and is unaffected by the liner;
  2. the slurry is bubbly or high-solids — the clamp-on long path drifts or loses lock, while the PS7000 short reflection plus Chirp wideband rejects bubbles and stays stable;
  3. operation is long and continuous — the clamp-on needs periodic couplant checks / re-application and re-calibration, while the PS7000 needs no couplant at all;
  4. accuracy and stability matter — the PS7000 is independent of the pipe wall and holds ±1 % FS, whereas clamp-on accuracy is affected by wall / liner / coupling;
  5. DCS integration or a hazardous-area rating is needed — the PS7000 offers 4-20 mA ×2 + RS485, with optional Ex d IIC T6 Gb and CE.

In short: the clamp-on wins on fast, movable mounting; the PS7000 wins on accurate, durable measurement. For lined, bubbly or long-running high-accuracy duty, evaluate the PS7000 first.

Where each fits

Condition

Clamp-on (transmission)

PS7000 (acoustic impedance)

Lined pipe (rubber / PTFE / ceramic / cement)

often not measurable

unaffected (window inside pipe)

Bubbly / high-solids slurry

drifts / loses lock

Keeps measuring, reports aeration index

Long continuous operation

periodic couplant re-apply, re-cal

No couplant to maintain

No shutdown / temporary · mobile

non-invasive, flexible (advantage)

one-time flange install

More on Ultrasonic Slurry Density Meter

Other comparisons